  1. Full AT Command Set Listing For SupraFAXModems
  2.  
  3. NOTE:   This file includes commands not available on all models & revisions.
  4.         Not all commands are available or functional in all modes & states.
  5.  
  6. AT_LIST.TXT  Rev 2.1  (PHM 6/4/93)  from Supra BBS (503)967-2444
  7.  
  8.  
  9. @       Dialing Command - wait for "quiet answer"
  10. ,       Dialing Command - pause (time set in S8) before finishing dialing string
  11. !       Dialing Command - hook flash (go on-hook for 700ms)
  12. ^       Dialing Command - turn on call originating tone
  13. ;       Dialing Command - return to command state after dialing (last command)
  14. +++     Default Escape Code
  15. A       Answer Phone Line
  16. A/      Re-execute Last Command (this command NOT preceded by AT)
  17. Bn      BELL/CCITT mode switch at 300 & 1200 bps
  18.          B0=CCITT
  19.          B1=BELL (default in North America)
  20. C1      Carrier Control Selection
  21.          Provided for backward compatibility only. Does nothing but return "OK"
  22. D       Dial Command
  23.          Dials any mixed string of dialing commands and the following list of
  24.          symbols: 0123456789ABCD#*
  25. En      Command Echo
  26.          E0=not echo
  27.          E1=do echo (default)
  28. F1      On-line State Character Echo Selection
  29.          Provided for backward compatibility only. Does nothing but return "OK"
  30. Hn      Hook Control
  31.          H0=On-Hook (Hang Up)
  32.          H1=Off-Hook (pick up phone line)
  33. In      Identification Codes
  34.          I0=SupraFAXModem product ID code
  35.          I1=ROM checksum
  36.          I2=Test Checksum (OK if correct, ERROR if not)
  37.          I3=ROM revision code
  38.          I4=Encrypted report of supported protocols
  39.          I5=Supra Copyright info.
  40.          I10=Supported Features (encoded - see end of text for listing)
  41. L       Dialing command - dials last string dialed (limitted to 40 characters)
  42. Ln      Speaker Volume
  43.          L0&L1   Low
  44.          L2      Medium (default)
  45.          L3      High
  46. Mn      Speaker Control
  47.          M0      OFF
  48.          M1      On until carrier is received (default)
  49.          M2      Always On
  50.          M3      On when answering/On only after dialing & until carrier detect
  51. Nn      Connection Rate when Originating Call
  52.          N0=Connect ONLY at rate set in S37 register
  53.          N1=Connect Normally (default)
  54. On      Return from COMMAND MODE to ONLINE state
  55.          O0=Return to ONLINE state
  56.          O1=Request a retrain & Return to ONLINE state
  57. P       Set Pulse Dialing
  58. Qn      Result Code Mode
  59.          Q0=Enabled (Default)
  60.          Q1=Disabled
  61.          Q2=Enabled when Originating, Disabled when answering
  62. R       Dialing command - reverse to answer mode after dialing
  63.          (this MUST be the last command in the dialing string)
  64. Sr?     Reports value in S register r
  65. SCr?    Reports value is SC register r
  66. Sr=n    Write value n into S register r
  67. SCr=n   Write value n into SC register r
  68. Sx      Dialing command - dials number stored in memory area x
  69. T       Set Tone Dialing
  70. Vn      Result Code mode select
  71.          V0=Numeric
  72.          V1=Verbose (default)
  73. W       Dialing command - wait for dial tone before finishing string
  74. Wn      Error Correction Result Code Selection
  75.          W0=CONNECT XXXX (DTE rate) (default)
  76.          W1=Report Error Correction Mode
  77.          W2=CONNECT XXXX (DCE rate)
  78. Xn      Dialing mode/CONNECT result codes
  79.          X0=Blind Dial (ignore Dialtone & Busy), send CONNECT
  80.          X1=Blind Dial, send CONNECT XXXX
  81.          X2=follow Dialtone, but ignore Busy, send CONNECT XXXX
  82.          X3=follow Busy, but ignore Dialtone, send CONNECT XXXX or BUSY
  83.          X4=send CONNECT XXXX, BUSY, or NO DIALTONE (default)
  84. Yn      Long Space Disconnect
  85.          Y0=Not active (default)
  86.          Y1=Active (see manual)
  87. Zn      Soft reset and Load Stored profile n (last functional command on line)
  88.          Z0=resets modem & loads stored profile 0
  89.          Z1=resets modem & loads stored profile 1
  90. &Cn     DCD signal control
  91.          &C0=DCD always on
  92.          &C1=DCD follows carrier state (ON when carrier present)
  93. &Dn     Modem reaction to DTR on to off transition greater than S25 setting
  94.               a  b  c  d  e  (Settings of &Qn)
  95.          &D0= N  1  3  3  1
  96.          &D1= 2  2  3  3  2
  97.          &D2= 3  3  3  3  3
  98.          &D3= 4  4  3  3  4
  99.  
  100.          List of modem reactions:
  101.  
  102.          N=No Action
  103.          1=Disconnect & send OK result code
  104.          2=Swith to asynchronous command state
  105.          3=Disconnect return to command state (Answer disabled while DTR is off)
  106.          4=Perform soft reset (like ATZ0)
  107.  
  108.          List of &Q states:
  109.          a. &Q0, &Q5, &Q8, or &Q9
  110.          b. &Q1
  111.          c. &Q2
  112.          d. &Q3
  113.          e. &Q4
  114.  
  115. &Fn     Load Factory Default Configuration
  116.          &F0     No flow control, No error correction, No data compression
  117.          &F1     MAC hardware flow control, correction & compression active
  118.          &F2     Hardware flow control, correction & compression active
  119.                  (&F2 is default for DOS, WINDOWS, AMIGA, & STAND ALONE units.)
  120. &Gn     Guard Tone Selection
  121.          &G0     Do Not generate guard tones   (Default)
  122.          &G1     Generate 550Hz guard tone     (not supported)
  123.          &G2     Generate 1800Hz quard tone    (not supported)
  124. &Jn     Phone Jack Selection
  125.          &J0     Select RJ-11, RJ-41, & RJ-45S (Default)
  126.          &J1     Select RJ-12 & RJ-13          (not supported)
  127. &Kn     Serial Port Flow Control
  128.          &K0=None
  129.          &K3=Bidirectional Hardware (RTS/CTS)
  130.          &K4=Software (XON/XOFF)
  131.          &K5=Transparent Software flow control
  132.          &K6=Software (XON/XOFF) & Hardware (RTS/CTS) flow control
  133. &Ln     Line Type Selection (&L0 is the only valid setting)
  134. &Mn     Same function as &Qn setting.
  135. &Pn     Pulse dialing MAKE/BREAK ratio
  136.          &P0 39%/61% make/break ratio at 10PPS {US/CANADA}  (Default)
  137.          &P1 33%/67% make/break ratio at 10PPS {UK/Hong Kong}
  138.          &P2 33%/67% make/break ratio at 20PPS {Japan}
  139. &Qn     Asynchronous/Synchronous Mode Selection
  140.          &Q0     Asynchronous Direct mode
  141.          &Q1     Synchronous Mode 1 (Terminal must support both modes.)
  142.                  Call placed Async, modem switches to Sync. When DTR is dropped
  143.                  modem returns to Async.
  144.          &Q2     Synchronous Mode 2 Modem dials number in stored location 0
  145.                  when DTR goes from LOW to HIGH.
  146.          &Q3     Synchronous Mode 3 Dial number manually on a telephone, and
  147.                  then bring DTR high to let the modems connect.
  148.          &Q4     Not Used
  149.          &Q5     Asynchronous Reliable Mode (most common default)
  150.          &Q6     Asynchronous Normal Mode
  151.          &Q7     Not used
  152.          &Q8     Asynchronous Reliable Mode w/o v.42/v.42bis
  153.          &Q9     Asynchronous Reliable Mode w/o MNP 2-5
  154. &Rn     RTS Synchronous Mode
  155.          &R0     CTS responds to RTS (default)
  156.          &R1     CTS always on unless &K3 is set
  157. &Sn     DSR Action Select
  158.          &S0 Always on (default)
  159.          &S1 Follows EIA specification
  160. &Tn     Modem test modes for trained technicians (you must set the serial port
  161.           at 2400 or 9600, and set the modem with AT&F0)
  162.          AT&T0   Terminate test in progress
  163.          AT&T1   Local Analog Loopback
  164.          AT&T3   Local Digital Loopback for remote modem
  165.          AT&T4   Grant request for Remote Digital Loopback (default)
  166.          AT&T5   Prohibit request for Remote Digital Loopback
  167.          AT&T6   Remote Digital Loopback
  168.          AT&T7   Remote Digital Loopback with self-test
  169.          AT&T8   Local Analog Loopback with self-test
  170. &V      Display Configuration Profiles
  171. &Wn     Write ACTIVE Profile to Stored Profile n
  172.          &W0     Writes to profile 0
  173.          &W1     Writes to profile 1
  174. &Xn     Synchronous Transmit Clock Source
  175.          &X0=Modem generated (default)
  176.          &X1=DTE supplied
  177.          &X2=Derived from the data carrier received from the remote modem.
  178. &Yn     Select Configuration Loaded at power-up
  179.          &Y0=Load profile 0 (default)
  180.          &Y1=Load profile 1
  181. &Zx=n   Write stored telephone number x (0 to 3) the number n.
  182. \An     Maximum MNP Block Size for Stream Links
  183.          \A0     64 characters
  184.          \A1     128 characters
  185.          \A2     192 characters (default)
  186.          \A3     256 characters
  187. \Bn     Transmit Break of length n x 100ms where n is 1 to 9
  188.          (Send Link Attention in MNP mode)
  189. \Gn     Modem-to-Modem XON/XOFF (software) flow control (ignored if &Q5)
  190.          \G0=Disabled (default)
  191.          \G1=Enabled
  192. \Kn     Break Processing Control (controls remote modem during MNP mode)
  193.          \K0,\K2,\K4     Enter command state without sending BREAK to remote
  194.          \K1             Clear Modem & Terminal Buffers & send BREAK to remote
  195.          \K3             Don't clear Buffers, but send BREAK to remote
  196.          \K5             Send BREAK to remote in sequence with any transmitted
  197.                         data (default)
  198. \Ln     MNP Block Transfer Control
  199.          \L0     Use Stream Mode for MNP Links (default)
  200.          \L1     Use Block Mode for MNP Links
  201. \N      Operating Mode
  202.          \N0     Normal Mode
  203.          \N1     Direct Mode
  204.          \N2     MNP Reliable Mode
  205.          \N3     AutoReliable Mode
  206. \O      Originate MNP Reliable Mode Request
  207. \Tn     Set Inactivity Timer (Modem disconnects if no activity in time n)
  208.          n=0             Timer disabled (default)
  209.          n=1 to 42       Modem disconnects after n minutes without activity
  210. \U      Accept MNP Reliable Request (request must occur within 12 seconds)
  211. \Y      Switch to MNP Reliable Mode
  212. \Z      Switch from MNP to Normal Mode
  213. %Cn     MNP5 Data Compression Enable/Disable
  214.          %C0     Disabled
  215.          %C1     Enabled
  216. %Dn     BTLZ Dictionary Size
  217.          %D0=512
  218.          %D1=1024
  219.          %D2=2048 (default)
  220.          %D3=4096 (if one-way compression %M1 or %M2 is enabled)
  221.              2048 (if two-way compression %M3)
  222. %En     Auto Retrain based on line monitor readings
  223.          %E0=Disabled (Default)
  224.          %E1=Enabled
  225. %Gn     Rate Renegotiation based on line monitor readings
  226.          %G0=Disabled
  227.          %G1=Enabled (Default)
  228. %L      Reports Received Signal Level nnn in -dBm.
  229.          nnn=9 or stronger       reports as 9
  230.          nnn=10 to 42            reports as value directly
  231.          nnn=43 or weaker        reports as 43
  232. %Mn     BTLZ Compression Mode
  233.          %M0     Disabled
  234.          %M1     Transmit compression only
  235.          %M2     Receive compression only
  236.          %M3     Two-way compresion (default)
  237. %P      Clear Local & Remote Modems' BTLZ Dictionaries
  238. %Q      Report Received signal Quality (nnn range 0 to 127)
  239.          nnn=1 to 8 current signal quality excellent (higher rate may be used)
  240.          nnn=9 to 20 current signal good (best carrier rate for line condition)
  241.          nnn=20 to 30 current signal poor (lower carrier rate should be used)
  242.          nnn=31 to 127 signal very bad (or gone), try forcing a lower rate
  243.          NOTE: Modem uses 8 and 20 as rate renegotiation watermarks.
  244. %Sn     Set Maximum BTLZ string length n (6 to 250)   (default is 32)
  245. #CID=n  Caller ID Mode
  246.          #CID=0  Disable Caller ID (Default)
  247.          #CID=1  Enable Formatted Caller ID Mode
  248.          #CID=2  Enable Raw (ASCII printable HEX number) Mode
  249.  
  250. S0=n    Number of Rings to Auto Answer (0 to 255) (0 is disable & default)
  251. S1=n    Number of Rings before last answer.
  252. S2=n    Escape Code character (0 to 255) (default is 43 "+")
  253. S3=n    Carriage Return character (0-127) (default is 13)
  254. S4=n    Line Feed character (0-127) (default is 10)
  255. S5=n    Backspace character (0-32) (default is 8)
  256. S6=n    Time to Wait before Blind Dial (2-255 seconds)  (default is 2)
  257.          (Applies only in X,X1, or X3 dialing mode)
  258. S7=n    Time to Wait for Carrier (1-255 seconds) (default is 50)
  259. S8=n    Pause Time for Comma Dial Command (0-255 seconds) (default is 2)
  260. S9=n    Time to Wait Before Recognizing Carrier (1-255 1/10 seconds)
  261.          (Default is 6)
  262. S10=n   Delay from Lost Carrier to Hang Up (1-255 1/10 seconds) (Default is 14)
  263. S11=n   DTMF Tone Duration/Spacing (35 to 120 1/1000 seconds) (Default is 95)
  264. S12=n   Escape Code Guard Time (0 to 255 1/50 seconds) (0 to disable, the
  265.          default is 50)
  266. S14     Bit Mapped Option State Codes
  267. S16     Diagnostic Test Mode setting -Bit Mapped (default 0)
  268.          0       &T1     0 Disable       1 Enable
  269.          1       Not Used
  270.          2       &T3     0 Disable       1 Enable
  271.          3       &T4/&T5 0 Off           1 In progress
  272.          4       &T6     0 Disable       1 Enable
  273.          5       &T7     0 Disable       1 Enable
  274.          6       &T8     0 Disable       1 Enable
  275.          7       Not Used
  276. S18=n   Test Mode Timer (0-255 seconds, 0=Runs endlessly)
  277. S21     Bit Mapped Option State Codes
  278. S22     Bit Mapped Option State Codes
  279. S23     Bit Mapped Option State Codes
  280. S25=n   Delay to DTR (0-255 1/100 seconds, 5 default)
  281. S26=n   RTS/CTS Delay (0-255 1/100 seconds, 1 default) (Sync mode only)
  282. S27     Bit Mapped Option State Codes
  283. S30=n   Inactivity Timer (0-255 Unit 10 seconds, 0=disable {default})
  284.          In Reliable mode any data transfer resets timer.
  285.          In Normal mode only sent data resets timer.
  286. S36=n   Negotiation Failure Treatment (0-7  7 is default)
  287.          Fallback options when S48=128 or error correction link fails:
  288.          0       Disconnect
  289.          1       Establish Direct connection
  290.          2       Undefined
  291.          3       Establish Normal connection
  292.          4       Establish a MNP connection if possible, else Disconnect
  293.          5       Establish a MNP connection if possible, else Direct connection
  294.          6       Undefined
  295.          7       Establish a MNP connection if possible, else Normal connection
  296. S37=n   Forced Single Carrier Rate (0-12  0 is default)
  297.          0       Carrier Rate at the rate the last AT command was issued.
  298.                  (If rate is above highest carrier rate, then the highest
  299.                  carrier rate the modem supports is used.)
  300.          1       300 bps
  301.          2-4     Undefined
  302.          5       1200 bps
  303.          6       2400 bps
  304.          7       Undefined
  305.          8       4800 bps
  306.          9       9600 bps
  307.          10      12000 bps
  308.          11      14400 bps
  309.          12      7200 bps
  310. S38=n   Delay Before Forced Disconnect (0-255 seconds, default 20)
  311.          0-254   Delay in seconds from H command, or DTR toggle ON or OFF (if
  312.                  modem is set to follow DTR), before modem disconnects.
  313.          255     Modem send data out of buffer until completed or connection
  314.                  is lost.
  315. S40     Bit Mapped Option State Codes
  316. S41     Bit Mapped Option State Codes
  317. S46=n   Protocol Selection (136 or 138) (Affects v.42/v.42bis mode)
  318.          136     Disable Compression
  319.          138     Enable Compression (default)
  320. S48=n   v.42 Negotiation (0,7,128)
  321.          0       Disable Negotiation, proceed with LAPM
  322.          7       Enable Negotiation (default)
  323.          128     Disable Negotiation, fallback per S36 setting
  324. S80=n   Enhanced Features (Bit Mapped Options)
  325.          Bit (Decimal)
  326.          0 (1)   Enable Access to functions in bits 1-7 of S80
  327.          1 (2)   Sync Clock Source
  328.          2 (4)   Sync Clock source
  329.          3 (8)   DTR/DSR always on
  330.          4 (16)  Enable lease line mode (If hardware supports)
  331.          5 (32)  Enable V.25bis codes
  332.          6 (64)  Enable remote configuation
  333.          7 (128) Enable passwd/callback
  334. S82=n   LAPM Break Handling Options (3,7,128)
  335.          3       Expedited: Modem sends break immediately & data integrity is
  336.                          maintained before and after break.
  337.          7       Destructive: Modem sends break immediately & data being
  338.                          processed by each modem at that time is destroyed.
  339.          128     In sequence: Modem sends break in sequence with transmitted
  340.                          data & data integrity is maintained before and after
  341.                          the break
  342. S86?    Report Connection Failure Cause Code
  343.          0      Normal disconnect
  344.          1-3    Undefined Error Code
  345.          4      Carrier loss
  346.          5      No error correction at other end
  347.          6      No response to feature negotiation
  348.          7      This modem is ASYNC only, other is SYNC
  349.          8      No framing technique in common
  350.          9      No protocol in common
  351.          10     Bad response to feature negotiation
  352.          11     No sync information from remote
  353.          12     Normal hangup initiated by remote
  354.          13     Retransmission limit reached
  355.          14     Protocol violation occured
  356.          15-255 Undefined Error Code
  357. S95=n   Extended Result Code Control (default sum is 0)
  358.          Each bit set high in this register enables the corresponding result
  359.          code regardless of the W command setting.
  360.         Bit (Decimal Value)
  361.          0 (1)   CONNECT XXXX result code gives DCE to DCE rate instead of
  362.                  local DTE to DCE rate.
  363.          1 (2)   Append /ARQ to verbose CONNECT result code if protocol is NONE
  364.          2 (4)   Enable CARRIER XXXX result code
  365.          3 (8)   Enable PROTOCOL XXXX result code
  366.          4 (16)  Undefined
  367.          5 (32)  Enable COMPRESSION result code
  368.          6 (64)  Undefined
  369.          7 (128) Undefined
  370. S109=n  v.32/v.32bis Negotiation Rate Selection (default sum is 62)
  371.          Each bit set high in this register enables the corresponding rate as
  372.          a valid rate to be used during rate negotiation.
  373.         Bit (Decimal Value)
  374.          0 (1)   Unused
  375.          1 (2)   4800 bps
  376.          2 (4)   7200 bps
  377.          3 (8)   9600 bps
  378.          4 (16)  12000 bps
  379.          5 (32)  14400 bps
  380.          6 (64)  Unused
  381.          7 (128) Unused
  382. S110=n  v.32/v.32bis Mode & Rate Negotiation Control
  383.          0       Normal v.32 mode (no v.32bis support)
  384.          1       Normal v.32bis mode
  385.          2       v.32bis mode with automatic rate renegotiation (default)
  386.          3       v.32bis mode with automatic rate renegotiation starting with
  387.                  the lowest rate set in S109 and working up one defined rate at
  388.                  a time toward the highest rate set in S109 (based on %Q level
  389.                  at each rate prior to stepping up.) (If the modem steps back
  390.                  down, it will also follow the S109 settings.)
  391.  
  392. SCn=n   BUSY Detect Watermark Controls
  393.          Each register "pair" holds the value for each setting.  To set a value,
  394.          divide the setting by 256.  The integer goes in the second register,
  395.          while the remained goes in the first.  (A setting of 516 would convert
  396.          to 2 Remainder 4, and could be set by sending ATSC0=4SC1=2 to the
  397.          modem.)  Settings are in 1/100ths of a second.
  398.         Default values:
  399.          Minimum BUSY ON Time
  400.           SC0=30
  401.           SC1=0
  402.          Maximum BUSY ON Time
  403.           SC2=75
  404.           SC3=0
  405.          Minimum BUSY OFF Time
  406.           SC4=30
  407.           SC5=0
  408.          Maximum BUSY OFF Time
  409.           SC6=75
  410.           SC7=0
  411.          (Defualts support FCC Spec. BUSY signal.  Setting SC0=25 & SC4=25
  412.           allows FAST BUSY to also be detected as BUSY.)
  413.  
  414. SC8=n   Set number of valid BUSY Pulses before reporting BUSY (4 is default)
  415.  
  416.  
  417.  
  418. FAX commands of special interest to Supra Users:
  419.  
  420.         +FAE=n  (CLASS 1 Only) Adaptive Answer / Silent Answer Mode Control
  421.                  0       Disable Both
  422.                  1       Adaptive Answer ONLY
  423.                  2       Adaptive Answer & Silent Answer
  424.                  3       Silent Answer ONLY
  425.         +FAA=n  (CLASS 2 Only) Adaptive Answer / Silent Answer Mode Control
  426.                  0       Disable Both
  427.                  1       Adaptive Answer ONLY
  428.                  2       Adaptive Answer & Silent Answer
  429.                  3       Silent Answer ONLY
  430.  
  431.  
  432. Connection Result Codes:
  433.  
  434. Nemeric Verbose
  435. 0       OK
  436. 1       CONNECT                 (300 bps)
  437. 2       RING
  438. 3       NO CARRIER
  439. 4       ERROR
  440. 5       CONNECT 1200
  441. 6       NO DIALTONE
  442. 7       BUSY
  443. 8       NO ANSWER
  444. 9       CONNECT 0600
  445. 10      CONNECT 2400
  446. 11      CONNECT 4800
  447. 12      CONNECT 9600
  448. 13      CONNECT 7200
  449. 14      CONNECT 12000
  450. 15      CONNECT 14400
  451. 16      CONNECT 19200
  452. 17      CONNECT 38400
  453. 18      CONNECT 57600
  454. 19      CONNECT 115200          (Not Currently Supported on MOST models)
  455. 22      CONNECT 1200/75         (Models with v.23 support only)
  456. 23      CONNECT 75/1200         (Models with v.23 support only)
  457.                                                                
  458. 40      CARRIER 300
  459. 44      CARRIER 1200/75         (Models with v.23 support only)
  460. 45      CARRIER 75/1200         (Models with v.23 support only)
  461. 46      CARRIER 1200
  462. 47      CARRIER 2400
  463. 49      CARRIER 7200
  464. 50      CARRIER 9600
  465. 51      CARRIER 12000
  466. 52      CARRIER 14400
  467.  
  468. 66      COMPRESSION: CLASS 5    (MNP 5)
  469. 67      COMPRESSION: V.42BIS    (BTLZ)
  470. 69      COMPRESSION: NONE
  471.  
  472. 70      PROTOCOL: NONE
  473. 77      PROTOCOL: LAP-M         (V.42)
  474. 80      PROTOCOL: ALT           (MNP)
  475.         FAX
  476.         DATA
  477.  
  478. V.32 & V.32BIS EXTERNAL DISPLAY CODES
  479.  
  480. Red LED's
  481.  
  482.         OH      Off Hook
  483.         RD      Receiving Data
  484.         SD      Sending Data
  485.         TR      Terminal Ready (Follows DTR per &Dn setting)
  486.  
  487. Green LED Display PANEL
  488.  
  489.         AA      Auto Answer (RI displayed during ring)
  490.         CD      Carrier Detected
  491.         DC      Data Compression in use
  492.         DI      Dialing
  493.         FX      FAX MODE
  494.         LP      LAPM Error Correction in use.
  495.         M2      MNP2 Error Correction in use.
  496.         M3      MNP3 Error Correction in use.
  497.         M4      MNP4 Error Correction in use.
  498.         M5      MNP5 Data Compression in use.
  499.         OK      Modem Powered Up Correctly and Ready for Use.
  500.         RE      Receive Error while using LAPM or MNP mode.
  501.         RI      Ring Indicator
  502.         RT      Retrain in progress
  503.         TE      Transmit Error while using LPAM or MNP mode.
  504.         TM      Test Mode in use.
  505.         3       300 bps connection
  506.         12      1200 bps connection
  507.         24      2400 bps connection
  508.         48      4800 bps connection
  509.         72      7200 bps connection
  510.         96      9600 bps connection
  511.         120     12000 bps connection
  512.         144     14400 bps connection
  513.                                    
  514. Encoded Optional Feature List (ATi10)
  515.         Code    Feature                         Added AT Commands & Result Codes
  516.         101     Fax CLASS 1                     Normal CLASS 1
  517.         104     Fax CLASS 2                     Normal CLASS 2
  518.         105     Fax CLASS 2.0                   Normal CLASS 3
  519.         115     CCITT v.17 (14.4 Fax)           See Above
  520.         120     Worldwide Support               %T      PTT Cert. Test Signals
  521.                                                 *NC?    Display Country Config.
  522.                                                 *NCn    Change County Config.
  523.         121     CCITT v.23                      %Fn (1-3)
  524.                                                 %F1     75T/1200R
  525.                                                 %F2     1200R/75T
  526.                                                 %F3     v.23 HALF DUPLEX
  527.                                                 Adds These Result Codes:
  528.                                                 #       Text
  529.                                                 22      CONNECT 1200TX/75RX
  530.                                                 23      CONNECT 75TX/1200RX
  531.                                                 44      CARRIER 1200/75
  532.                                                 45      CARRIER 75/1200
  533.         122     CCITT v.25                      See Software Doc.s
  534.         123     Blacklisting                    *B      Display Blacklisted #'s
  535.                                                 *D      Display Delayed #'s
  536.                                                 Adds These Result Codes:
  537.                                                 24      DELAYED
  538.                                                 32      BLACKLISTED
  539.         124     Access Security                 *C      Enb. Sec. Acc. & Req.PW
  540.                                                 *E      Exit Sec. Access
  541.                                                 *L      List PW & CB directories
  542.                                                 *P      Stores PassWords
  543.                                                 *R      Request Sec. Acc. Mode
  544.         140     CCITT v.32bis (14.4 Data)       See Above
  545.         141     Silent Answer                   See Above
  546.         142     Caller ID                       See Above
  547.         143     MNP 10                          -B      Forced FB to 1200
  548.                                                 -C      MNP10 Sync Mode
  549.                                                 -C1     MNP10 Async Mode
  550.                                                 -C2     MNP 2
  551.                                                 -C3     MNP 3
  552.                                                 -K      No LAPM to MNP10 Conv.
  553.                                                 -K1     Conv. LAPM to MNP10
  554.                                                 -Q      FB to v.22/v.22bis
  555.                                                 -Q1     No FB to v.22/v.22bis
  556.                                                 -Un  Tx Level Change during FF
  557.                                                 -U0     auto attn to -10dBm
  558.                                                 -U1     auto attn to -18dBm
  559.                                                 -U2     auto attn to -22dBm
  560.                                                 -U3     auto attn to -25dBm
  561.                                                 -U4     Force 2400 to -10dBm
  562.                                                 -U5     Force 2400 to -18dBm
  563.                                                 -U6     Force 2400 to -22dBm
  564.                                                 -U7     Force 2400 to -25dBm
  565.                                                 )M      Tx fixed at -10dBm
  566.                                                 )M1     Tx attempt Tx < -10dBm
  567.                                                 *H0     Link Neg. at Top Speed
  568.                                                 *H1     Link Neg. at 1200
  569.                                                 *H2     Link Neg. at 4800
  570.         144     MNP "Cellular"
  571.         145     AutoSync
  572.         146     Enhanced Configuration Display  \S      Enhanced Display Codes
  573.         160     Voice Processing                In Upgrade Doc. for Option
  574.